Industrial 1.50 meters Sensor cable M12A 5-pin male to M12A 5-pin female, Superflex Xtreme TPE cable, shielded
Item No.
SC3501
- Flexible TPE sheath
- Full copper Superflex Xtreme AWG22 shielded cable
- UL
- IP67
- A-Coded
The ACT Industrial sensor cables (actor cables) are provided with a TPE (Thermo Plastic Elastomer) sheath and are therefore highly resistant to mechanical loads such as movements in a chain. The connectors are overmoulded TPE and degree of protection is IP67.
Superflex Xtreme cable, each individual core consists of 19 strands of copper that together form a diameter of AWG22. This makes the cable more flexible than, for example, a standard AWG24/7 patch cable.
Stranded conductors are build up of uninsulated thin strands of wire twisted together.
How greater the number of strands in a stranded conductor, the greater the flexibility of the wire.
Superflex Xtreme cable, each individual core consists of 19 strands of copper that together form a diameter of AWG22. This makes the cable more flexible than, for example, a standard AWG24/7 patch cable.
Stranded conductors are build up of uninsulated thin strands of wire twisted together.
How greater the number of strands in a stranded conductor, the greater the flexibility of the wire.
Description
- Flexible TPE sheath
- Full copper Superflex Xtreme AWG22 shielded cable
- UL
- IP67
- A-Coded
The ACT Industrial sensor cables (actor cables) are provided with a TPE (Thermo Plastic Elastomer) sheath and are therefore highly resistant to mechanical loads such as movements in a chain. The connectors are overmoulded TPE and degree of protection is IP67.
Superflex Xtreme cable, each individual core consists of 19 strands of copper that together form a diameter of AWG22. This makes the cable more flexible than, for example, a standard AWG24/7 patch cable.
Stranded conductors are build up of uninsulated thin strands of wire twisted together.
How greater the number of strands in a stranded conductor, the greater the flexibility of the wire.
Superflex Xtreme cable, each individual core consists of 19 strands of copper that together form a diameter of AWG22. This makes the cable more flexible than, for example, a standard AWG24/7 patch cable.
Stranded conductors are build up of uninsulated thin strands of wire twisted together.
How greater the number of strands in a stranded conductor, the greater the flexibility of the wire.
Specifications
Product category | Sensor cables |
Cable length | 1.5 m |
Connector type | M12 |
Connector A | M12 5-pin male (x1) |
Coding | A-coding |
Connector B | M12 5-pin female (x1) |
Connector design | Axial |
Contacts | 5 |
Contact material | Brass |
Contact plating | Gold plated |
Housing colour | Black |
Locking | Screwable |
Shielding type | Aluminum Mylar, Braid |
Shielded | Yes |
Degree of protection | IP67 |
Conductor material | Copper |
Wire gauge | 22 AWG |
Outer jacket | TPE |
Cable colour | Black |
Colour number | RAL 8022 |
Rated voltage | 300 V |
Min. working temperature | -40 °C |
Max.working temperature | 105 °C |
Approval | UL, UL94-V0 |
EAN code | 8716065524215 |
Downloads / Drivers